commit 336306790b2bbf7ce837625fa3b24ba724d05838 upstream.
BMI160 Minimium gyroscope frequency in normal mode is 25Hz.
When older EC firmware do not report their sensors frequencies,
use 25Hz as the minimum for gyroscope to be sure it works on BMI160.
Fixes: ae7b02ad2f32d ("iio: common: cros_ec_sensors: Expose cros_ec_sensors frequency range via iio sysfs")
Signed-off-by: Gwendal Grignou <gwendal@chromium.org>
Reviewed-by: Enric Balletbo i Serra <enric.balletbo@collabora.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
commit e450e07c14abae563ad13b064cbce9fdccc6bc8d upstream.
Indeed, relying on addr being not 0 cannot work because some device have
their register to set odr at address 0. As a matter of fact, if the odr
can be set, then there is a mask.
Sensors with ODR register at address 0 are: lsm303dlh, lsm303dlhc, lsm303dlm
Fixes: 7d245172675a ("iio: common: st_sensors: check odr address value in st_sensors_set_odr()")
Signed-off-by: Lary Gibaud <yarl-baudig@mailoo.org>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>